Our Capabilities

Hyperbaric Chamber

A test stand for hyperbaric trials: depth conditions are simulated and every parameter is logged in real time.

Contact Us → Stand Capabilities

Stand Capabilities

01

Penetrators

DN150 — 3 pcs, DN100 — 4 pcs, DN40 — 14 pcs.

02

Maximum Pressure

Depth simulation down to 450 m at working pressures up to 4.5 MPa.

03

Test Monitoring

Process parameters are logged in real time by the chamber’s own control system, without operator involvement.

04

Specimen Dimensions

Up to 2200 mm high and up to 1 m in diameter.

05

Energised Testing

Hyperbaric trials can be run with the equipment energised at up to 2800 V.

The hyperbaric test chamber is designed for hyperbaric testing of equipment and for a comprehensive assessment of its serviceability, structural strength and resistance to elevated pressure. The stand reproduces operating conditions down to 450 m and runs trials in a controlled environment, logging the principal process parameters in real time.

The chamber is used to test equipment under elevated pressure, to verify the serviceability of technical systems and products at pressures up to 4.5 MPa, and to simulate subsea operating conditions at a given depth.

Chamber design

Hyperbaric chamber: general view with the lid removed
General view, lid removed
Hyperbaric chamber: front view
Front view
Hyperbaric chamber: top view with the lid open
Top view, lid open

Sealed penetrators

To connect the specimen and external measuring systems, the test chamber is fitted with sealed penetrators:

  • DN150 — 3 pcs
  • DN100 — 4 pcs
  • DN40 — 14 pcs

The penetrator design holds its seal at working pressures, prevents leaks and keeps the specified hyperbaric test conditions stable.

Test monitoring and logging

All principal process parameters can be logged automatically and in real time by the chamber’s own control system. This keeps the test under control throughout the cycle, records pressure changes and other monitored values, and yields objective data for subsequent analysis of the results.

Key specifications

Type of testingHyperbaric trials, elevated-pressure testing
Depth simulationDown to 450 m
Maximum working pressureUp to 4.5 MPa
Specimen dimensionsUp to 2200 mm high, up to 1000 mm in diameter
Test voltageUp to 2800 V
PenetratorsDN150 — 3 pcs; DN100 — 4 pcs; DN40 — 14 pcs
Parameter loggingAutomatic, in real time
Control systemThe chamber’s own control system

The chamber in photographs

ENERCOM-SA hyperbaric chamber
ENERCOM-SA hyperbaric chamber
ENERCOM-SA hyperbaric chamber
ENERCOM-SA hyperbaric chamber
ENERCOM-SA hyperbaric chamber

Shall we discuss testing your equipment?